Original Features
Type | Nominal load (kN) |
Stoke (mm) |
A min (mm) |
A half stroke (mm) |
A MAX (mm) |
0B (mm) |
C (mm) |
0D (mm) |
E (mm) |
F (mm) |
0G (mm) |
H min (mm) |
H half stroke (mm) |
H max (mm) |
0I |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HAS-EA-AN01 | 10 | 100 | 467 | 527 | 587 | 81 | 52 | 20 | 20 | 17 | 47 | 356 | 456 | 586 | 42.7 |
200 | 590 | 700 | 810 | ||||||||||||
HAS-EA-AN02 | 20 | 100 | 491.5 | 551.5 | 611.5 | 85 | 65 | 25 | 25 | 22 | 58 | 369 | 469 | 599 | 42.7 |
200 | 555.5 | 665.5 | 775.5 | ||||||||||||
HAS-EA-AN03 | 30 | 100 | 499.5 | 599.5 | 619.5 | 100 | 60 | 30 | 22 | 28 | 64 | 364 | 464 | 594 | 48.6 |
200 | 625.5 | 735.5 | 845.5 | ||||||||||||
300 | 751.5 | 911.5 | 1071.5 | ||||||||||||
HAS-EA-AN05 | 50 | 100 | 515.5 | 575.5 | 635.5 | 109 | 70 | 35 | 25 | 30 | 78 | 374 | 474 | 604 | 60.5 |
200 | 649.5 | 759.5 | 869.5 | ||||||||||||
300 | 777.5 | 937.5 | 1097.5 | ||||||||||||
HAS-EA-AN07 | 70 | 100 | 570 | 630 | 690 | 124 | 97 | 40 | 40 | 33 | 90 | 403 | 503 | 633 | 60.5 |
200 | 699 | 809 | 919 | ||||||||||||
300 | 828 | 988 | 1148 | ||||||||||||
HAS-EA-AN10 | 100 | 100 | 568 | 628 | 688 | 135 | 97 | 40 | 40 | 33 | 90 | 403 | 503 | 613 | 76.3 |
200 | 698 | 808 | 918 | ||||||||||||
300 | 828 | 988 | 1148 | ||||||||||||
HAS-EA-AN12 | 120 | 100 | 569 | 629 | 689 | 146 | 97 | 40 | 40 | 33 | 90 | 403 | 503 | 613 | 76.3 |
200 | 700 | 810 | 920 | ||||||||||||
300 | 830 | 990 | 1150 | ||||||||||||
HAS-EA-AN15 | 150 | 100 | 587 | 647 | 707 | 157 | 105 | 50 | 35 | 40 | 116 | 409 | 509 | 619 | 89.1 |
200 | 718 | 828 | 938 | ||||||||||||
300 | 849 | 1009 | 1169 |
Product Performance
Design Parameter | Criteria |
---|---|
Drag Force | Less than 3 ~ 5% of the Max. rated load |
Release Rate | 0 ~ 0.5mm/sec |
Lock-up velocity/acceleration | 1 ~ 4mm/sec |
Reference Standards
Division-1
NF (KEPIC MNF)
ISTD (KEPIC MOE)
Certificate & Patent
Pipe shock absorber
Hydraulic pipe shock absorber
Hydraulic pipe shock absorber
Hydraulic snubber [Pipe shock absorber]
Track Records
- Indonesia | KPJB - Tanjung Jati pp. #1, 2
- Indonesia | Paiton pp. #9
- KOWEPO - Taean pp. #3
- KOWEPO - Seo-Incheon pp. #2, 4, 7 (HRSG&ST)
- KOMIPO - Boryeong pp. #5
- KOMIPO - Boryeong combined cycle #1, 2
- KOSPO - Shin-Incheon pp. #3, 4
- Indonesia | KPJB - Tanjung Jati pp. #4
- KOWEPO – Taean pp. #3, 4
- Malaysia | Panglima Power - Telok Gong power station #3
- Philippines | KEPCO - Cebu pp. #1
- Indonesia | Indonesia power - Adipala pp. #1
- KOWEPO – Taean pp. #3
- Indonesia I KPJB - Tanjung Jati pp. #4
- Indonesia I PT. Cogindo Dayabersama - Semarang CCPP #2, 3
- Indonesia | KPJB - TanjungJati pp. #4
- The Philippines | Team Energy - Pagbilao pp. #1~2
- KOWEPO - Taean pp. #1
- Malyasia | Limut pp.
- Indonesia | KPJB - Tanjung Jati pp. #3
- Indonesia | KPJB - Tanjung Jati pp. #3
- KOWEPO - Taean pp. #2
- Thailand | KOMIPO - Navanakorn pp.
- Philippines | Team Energy - Pagbilao pp. #1
- Indonesia | PLN - Tanjung Jati pp. #4
- KOEN | Yeongdong power plant #2
- KOMIPO | Sejong pp.
- Saudi Arabia | ROMCO - Rabigh pp.
- Nigeria | EGBIN pp. #1, 5
- Saudi Arabia | ROMCO - Rabigh pp.
- Nigeria | EGBIN pp. #4
- Malaysia | TNB REMACO - Janamanjung pp. #1~3
Multiaxial Hydraulic Snubber Multiaxial Hydraulic Pipe Shock Absorber
A supporting safeguard device that curbs various types of troubles arising from dynamic loads generated in & outside of the power generation facility including main equipment and pipelines, while avoiding the creation of additional thermal stresses by absorbing the designed thermal displacement.
This Multiaxial hydraulic pipe shock absorber is so sophistically designed and fabricated to respond to and absorb the shocks in random directions, breaking through the one-dimensional performance of the conventional shock absorber limited to responding to only one direction.
The Need
The need arose to design and engineer a compatible device that not only never restrains the movement of the piping even when 3D displacement different from the design breaks out, but also protects the piping and the main equipment from the strikes of dynamic loads of random directions.
Venue Photo
Product Performance
Design Parameter | Criteria |
---|---|
Drag Force | 2% of the rated load or 50Kgf. |
Bleed Rate | 0.1~2.0mm/sec |
Lock-up Rate | 2 ~ 6mm/sec |
Multiaxial Function | 34° |
Reference Standards
ISTD
Certificate & Patent
Multiaxial pipe shock absorber
Hydraulic shock absorber performance test device
Shock absorber performance evaluation system and its hydraulic control method
Track Records
- KOEN - Yeongdong power plant #2
- KOMIPO - Boryeong pp. #4
- KOMIPO - Sejong pp. #2
- KOMIPO - Sejong pp.
- KOMIPO - Boryeong pp. #3
- KOMIPO - Sejong pp.
- KOMIPO - Jeju pp.
- KOEN - Yeongdong pp. #1
- KOMIPO - Sejong pp.
- KOWEPO - Pyeongtaek pp. #4
- KOMIPO - Sejong pp.
- Malaysia | TNB REMACO - Janamanjung pp. #1~3
- Malaysia | TNB REMACO - KEV #5~6
- Malaysia | TNB REMACO - Janamanjung pp. #2
- KOMIPO - Boryeong pp. #4